Nova Hospital Glucose Monitoring System

Nova Hospital Glucose Monitoring System
statstrip-xpress Laboratory Quality Accuracy from 0.5-33.3 mmol/L (10 to 600 mg/dL ) Only Bedside Meter to Eliminate Errors Caused by Hematocrit, Maltose, Galactose, Oxygen, and Electrochemical Interferences statstrip-hematocrit statstrip-strips statstrip-glucose-meters

Eliminates Interferences Due to Hematocrit, Maltose, Galactose, Oxygen, Paracetamol, Ascorbic Acid, and Uric Acid

Eliminates Calibration Codes

Laboratory Quality Accuracy at Extended Hypo and Hyperglycemic Ranges

Fast, 6 Second Results

Small, 1.2 Microliter Sample

Simple, Color Touch Screen Operation

Flexible POC Control

StatStrip Multi-WellTM Technology Delivers Lab-Like Analytical Performance

The Nova Biomedical StatStrip Glucose Monitoring System features a patented Multi-Well measuring technology that meets the escalating demands of today’s hospital glucose testing. StatStrip technology elevates bedside glucose monitoring to a level of accuracy, precision, and patient safety that approaches the quality of central laboratory testing.

The StatStrip design incorporates a feature to prevent glucose errors due to over-filling or under-filling of the sensor. Rapidfill electrochemically monitors the blood volume in each of the four measurement wells. Results are reported only if all four measurement wells are filled with blood.

Measures and Eliminates Hematocrit Interferences


800 Bed Teaching Hospital, Rochester, MN

StatStrip is the only bedside glucose meter to measure and eliminate glucose errors due to varying hematocrit levels. One of StatStrip’s four measuring wells measures hematocrit.

Hematocrit interferences can cause errors as large as 40%.

  • Can cause undetected hypoglycemia
  • Can cause insulin overdose

Severe hematocrit abnormalities are very common in ICUs.

  • Up to 77% of ICU patients have low hematocrit levels
  • Nearly half of ICU patients require red cell transfusions due to low hematocrit. Average hematocrit of these patients pre-transfusion is 22-25%


Only Bedside Meter to Eliminate Errors Caused by Hematocrit, Maltose, Galactose, Oxygen, and Electrochemical Interferences


Laboratory Quality Accuracy from 0.5-33.3 mmol/L (10 to 600 mg/dL)

Eliminates Calibration Codes

StatStrip’s patented Multi-Well technology provides such strict consistency that calibration codes are not necessary.

  • Errors due to coding are eliminated
  • Testing steps are reduced
  • Strip lots can be used interchangeably

StatStrip Xpress


The StatStrip Xpress meter is an option for hospitals or clinics which do not need data interface/connectivity capability.

  • Uses same Multi-Well test strip
  • Provides same laboratory quality analytical performance
  • Xpress meter is simple, fast and easy to use

Product Website: Nova Biomedical Product Page